Difference between revisions of "NPS Calo How-To"
From HallCWiki
Jump to navigationJump to searchLine 1: | Line 1: | ||
− | [https://hallcweb.jlab.org/wiki/index.php/Hall_C_DAQ NPS-HMS DAQ in Hall C] | + | *[https://hallcweb.jlab.org/wiki/index.php/Hall_C_DAQ NPS-HMS DAQ in Hall C] |
<!-- | <!-- | ||
[https://wiki.jlab.org/cuawiki/index.php/NPS_DAQ_in_Hall_C NPS DAQ in Hall C] | [https://wiki.jlab.org/cuawiki/index.php/NPS_DAQ_in_Hall_C NPS DAQ in Hall C] | ||
--> | --> | ||
+ | **[https://logbooks.jlab.org/entry/4164991 how to get to the vtp trigger configuration] | ||
+ | **[https://logbooks.jlab.org/entry/4170042 vtp & v1495 Firmware update 8/23/2023] | ||
+ | **[[Media:NPS_VTP_DAQ.pdf | NPS_VTP_DAQ.pdf: A brief guide to the structure of the FADC250/VTP/V1495 NPS Calorimeter DAQ]] | ||
*[[NPS_Calo_SlowControls]] | *[[NPS_Calo_SlowControls]] | ||
Line 10: | Line 13: | ||
**[https://logbooks.jlab.org/entry/4169684 Idiosyncracies of the NPS Low Voltage power supply and controls] | **[https://logbooks.jlab.org/entry/4169684 Idiosyncracies of the NPS Low Voltage power supply and controls] | ||
− | Setting the Calorimeter angle (SMHS carriage): | + | *Setting the Calorimeter angle (SMHS carriage): |
− | *[[Media:C2082_NPS-Survey.pdf | NPS Survey Results]] | + | **[[Media:C2082_NPS-Survey.pdf | NPS Survey Results]] |
− | * SHMS angle (as defined in magnet gui) = Desired Calo Angle + Offset | + | ** SHMS angle (as defined in magnet gui) = Desired Calo Angle + Offset |
** Average offset 16.289 deg. | ** Average offset 16.289 deg. | ||
** To set SHMS angle, use universal offset 16.27 deg. Corrections can be made in analysis | ** To set SHMS angle, use universal offset 16.27 deg. Corrections can be made in analysis | ||
** Setting the SHMS to angles less than 28 deg (NPS < 11.7 deg) requires tech support and two people in the hall | ** Setting the SHMS to angles less than 28 deg (NPS < 11.7 deg) requires tech support and two people in the hall | ||
+ | <!-- | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 33: | Line 37: | ||
| style="background: #ffffff; color: #000000; font-weight: normal; font-style: normal; text-decoration: none; font-size: 10pt; text-align: left; vertical-align: bottom; border: 0px; width: 160px; height: 21px; " | 16.2718 deg | | style="background: #ffffff; color: #000000; font-weight: normal; font-style: normal; text-decoration: none; font-size: 10pt; text-align: left; vertical-align: bottom; border: 0px; width: 160px; height: 21px; " | 16.2718 deg | ||
|} | |} | ||
− | + | --> | |
− | + | * [https://halldweb.jlab.org/detectors/fcal2/pmt/Pub-97-092.pdf FermiLab Pub-97-092 on R4125 PMT performance (including lifetime)] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | [https://halldweb.jlab.org/detectors/fcal2/pmt/Pub-97-092.pdf FermiLab Pub-97-092 on R4125 PMT performance (including lifetime)] |
Revision as of 20:08, 16 September 2023
- Setting the Calorimeter angle (SMHS carriage):
- NPS Survey Results
- SHMS angle (as defined in magnet gui) = Desired Calo Angle + Offset
- Average offset 16.289 deg.
- To set SHMS angle, use universal offset 16.27 deg. Corrections can be made in analysis
- Setting the SHMS to angles less than 28 deg (NPS < 11.7 deg) requires tech support and two people in the hall
- FermiLab Pub-97-092 on R4125 PMT performance (including lifetime)