Difference between revisions of "Detector Working Group Meetings"
From HallCWiki
Jump to navigationJump to search (→HMS) |
|||
Line 39: | Line 39: | ||
|- | |- | ||
| | Attenuation Length Correction | | | Attenuation Length Correction | ||
+ | |- | ||
+ | | Cherenkov || Gain Calibration || ? | ||
+ | |- | ||
+ | | Shower/Pre-Shower || Gain Calibration || ? | ||
+ | |- | ||
+ | |} | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == SHMS == | ||
+ | |||
+ | {| border="1" cellpadding="2" valign="top" style="text-align: center;" | ||
+ | !width="250"| Detector System | ||
+ | !width="450"| Calibrations | ||
+ | !width="250"| Ready for Physics | ||
+ | |- | ||
+ | | Noble Gas Cherenkov || Gain Calibration || ? | ||
+ | |- | ||
+ | | rowspan ="3" | Drift Chambers | ||
+ | | t0 Offsets | ||
+ | | rowspan="3" | ? | ||
+ | |- | ||
+ | | | Drift Distance | ||
+ | |- | ||
+ | | | Alignment | ||
+ | |- | ||
+ | | rowspan ="3" | Hodoscopes | ||
+ | | Time-Walk Corrections | ||
+ | | rowspan="3" | ? | ||
+ | |- | ||
+ | | | Propagation Time Correction | ||
+ | |- | ||
+ | | | Attenuation Length Correction | ||
+ | |- | ||
+ | | Heavy Gas Cherenkov || Gain Calibration || ? | ||
|- | |- | ||
| Aerogel || Gain Calibration || ? | | Aerogel || Gain Calibration || ? | ||
− | |||
− | |||
|- | |- | ||
| Shower/Pre-Shower || Gain Calibration || ? | | Shower/Pre-Shower || Gain Calibration || ? |
Revision as of 16:32, 6 April 2017
General Information
- The aim of the detector working group meetings is to assess the current status of the Hall C detector systems in preparation for the upcoming run periods
Blue Jeans Connection Information
- https://bluejeans.com/895800575
- Just want to dial in on your phone?
- +1.408.740.7256 (US)
- +1.888.240.2560 (US Toll Free)
- +1.408.317.9253 (Alternate number)
- http://bluejeans.com/numbers
- Enter Meeting ID: 895800575
- Press #
Detector Statuses
Spring 2017 Run
HMS
Detector System | Calibrations | Ready for Physics |
---|---|---|
Drift Chambers | t0 Offsets | ? |
Drift Distance | ||
Alignment | ||
Hodoscopes | Time-Walk Corrections | ? |
Propagation Time Correction | ||
Attenuation Length Correction | ||
Cherenkov | Gain Calibration | ? |
Shower/Pre-Shower | Gain Calibration | ? |
SHMS
Detector System | Calibrations | Ready for Physics |
---|---|---|
Noble Gas Cherenkov | Gain Calibration | ? |
Drift Chambers | t0 Offsets | ? |
Drift Distance | ||
Alignment | ||
Hodoscopes | Time-Walk Corrections | ? |
Propagation Time Correction | ||
Attenuation Length Correction | ||
Heavy Gas Cherenkov | Gain Calibration | ? |
Aerogel | Gain Calibration | ? |
Shower/Pre-Shower | Gain Calibration | ? |
Hall C Detectors and System Owners
Beam Line
- Beam Line: D. Gaskell
Trigger & DAQ
- Trigger & DAQ: B. Sawatzky, E. Pooser
HMS
- 6 GeV Drift Chambers: E. Pooser
- 12 GeV Drift Chambers: L. Tang
- Hodoscopes: S. Malace
- Shower/Pre-Shower: H. Mkrtchyan, Yerevan
- Aerogel Cerenkov: A. Mkrtchyan, T. Horn
- HGC: E. Pooser
SHMS
- GEM: E. Pooser, M. Jones
- Drift Chambers: E. Christy, D. Biswas
- Hodoscopes: S. Malace
- Shower/Pre-shower: H. Mkrtchyan, Yerevan
- Aerogel Cerenkov: A. Mkrtchyan, T. Horn
- NGC: D. Day, E. Pooser
- HGC: G. Huber, B. Li