Difference between revisions of "Testing SHMS Preshower"

From HallCWiki
Jump to navigationJump to search
(New page: Category:SHMSinfo == Status == * The preshower has been cabled with signal and HV. * Have checked setting each channel to 1400V that signal is seen. == Computer Setup == * Computer is ...)
 
Line 7: Line 7:
 
== HV Setup ==
 
== HV Setup ==
 
* Can control the CAEN 403 through terminal on ''hallcn5''.
 
* Can control the CAEN 403 through terminal on ''hallcn5''.
 +
[https://hallcweb.jlab.org/wiki/images/9/9c/Pre_Shower_Cabeling.pdf pdf file ]

Revision as of 12:44, 29 May 2012

Status

  • The preshower has been cabled with signal and HV.
  • Have checked setting each channel to 1400V that signal is seen.

Computer Setup

  • Computer is called hallcn5. The account is cdaq.

HV Setup

  • Can control the CAEN 403 through terminal on hallcn5.

pdf file