Difference between revisions of "SHMS Optics Working Group"
From HallCWiki
Jump to navigationJump to searchLine 7: | Line 7: | ||
== Preparation plans == | == Preparation plans == | ||
− | * | + | * Magnets. |
− | * Double check that the magnet field between magnets are superpositions. | + | **Determination of B versus I curve. |
+ | **Cycling procedure especially for HB. Look what is done for the HMS. | ||
+ | ** Double check that the magnet field between magnets are superpositions. | ||
+ | ** Survey of the positioning of magnets. | ||
+ | * Check if it is possible to do carbon elastics at 2 pass. Dipangkar will look into this. | ||
* Survey of collimators, detectors and beamline components. | * Survey of collimators, detectors and beamline components. | ||
− | * Survey of HMS/SHMS pointing at different angles. | + | * Survey of HMS/SHMS pointing at different angles. Look into what was done in the past for HMS commissioning. Determine a list of angles for survey. |
− | + | * Need to come up with the sieve pattern as a function of quad settings. | |
+ | * Need to look at use of ideal dipole versus TOSCA field map for HB in COSY. | ||
+ | * Check with Howard about checking the quad field centering. | ||
+ | * Integration of detector checkout and optics. | ||
== SLITS and COLLIMATORS == | == SLITS and COLLIMATORS == |
Revision as of 12:32, 18 February 2016
Weekly Meetings
- Meetings will be held on Thursdays 11:30-12:30 in F228.
- Next meeting Feb 18th.
- Join by Bluejeans by phone and computer +1.888.240.2560 (US Toll Free) Enter Meeting ID: 653182486
Preparation plans
- Magnets.
- Determination of B versus I curve.
- Cycling procedure especially for HB. Look what is done for the HMS.
- Double check that the magnet field between magnets are superpositions.
- Survey of the positioning of magnets.
- Check if it is possible to do carbon elastics at 2 pass. Dipangkar will look into this.
- Survey of collimators, detectors and beamline components.
- Survey of HMS/SHMS pointing at different angles. Look into what was done in the past for HMS commissioning. Determine a list of angles for survey.
- Need to come up with the sieve pattern as a function of quad settings.
- Need to look at use of ideal dipole versus TOSCA field map for HB in COSY.
- Check with Howard about checking the quad field centering.
- Integration of detector checkout and optics.
SLITS and COLLIMATORS
Detector Positions
- Detector_Locations_in_SHMS location
SHMS Characteristics
Drawings of magnets
Study of the SHMS resolution
- Study of the SHMS resolution.
SNAKE
Moved Snake section here.