Difference between revisions of "SHMS Optics Working Group"

From HallCWiki
Jump to navigationJump to search
Line 13: Line 13:
 
** see [https://hallcweb.jlab.org/wiki/index.php/SHMS_Optics_Working_Group#HMS_and_SHMS_Dipoles HMS and SHMS Dipole section]
 
** see [https://hallcweb.jlab.org/wiki/index.php/SHMS_Optics_Working_Group#HMS_and_SHMS_Dipoles HMS and SHMS Dipole section]
 
* Double check to understand why there is a 0.7% difference between field at +3900A and -3900A.
 
* Double check to understand why there is a 0.7% difference between field at +3900A and -3900A.
 +
** The probe readings had not been corrected.
 
* Change the effective length of HB by 4% to see effects on the optics. Look at sieve.
 
* Change the effective length of HB by 4% to see effects on the optics. Look at sieve.
 
* Need table for conversion of all magnet currents to momentum.
 
* Need table for conversion of all magnet currents to momentum.

Revision as of 10:55, 29 March 2016

Weekly Meetings

  • Meetings will be held on Thursdays 11:30-12:30 in F228.
  • Next meeting March 31st.
  • Join by Bluejeans by phone and computer +1.888.240.2560 (US Toll Free) Enter Meeting ID: 653182486

Notes from March 10th meeting

  • Need to check whether the beam pipe will allow one to go to 8-9.5 degrees. (Dave Gaskell will look into this.)
  • Get the Q1 mapping information from Steve Lassiter.
  • Need to keep track of detector surveys. Contact Bert Metzger.
  • Put code for setting field on wiki.
  • Double check to understand why there is a 0.7% difference between field at +3900A and -3900A.
    • The probe readings had not been corrected.
  • Change the effective length of HB by 4% to see effects on the optics. Look at sieve.
  • Need table for conversion of all magnet currents to momentum.
  • Check with Steve Lassiter about what is exactly thinking of using to mitigate the HB stray fields. Wedges + C-section + iron pipe?
  • Work on run plans. (Rolf and Tanja)

Preparation plans

  • Magnets.
    • Determination of B versus I curve. Develop new code for setting SHMS. Revise HMS field setting codes.
    • Cycling procedure especially for HB. Look what is done for the HMS.
    • Double check that the magnet field between magnets are superpositions.
    • Survey of the positioning of magnets.
  • Carbon elastics at 2 pass.
  • Survey of collimators, detectors and beamline components.
  • Survey of HMS/SHMS pointing at different angles. Look into what was done in the past for HMS commissioning. Determine a list of angles for survey.
  • Need to come up with the sieve pattern as a function of quad settings.
  • Need to look at use of ideal dipole versus TOSCA field map for HB in COSY.
  • Checked with Howard about the quad field centering. The idea that Howard had didn't work. Need to rely on mapping data.
  • Integration of detector checkout and optics.

Carbon elastics

  • Results from Dipangkar for 1 pass- 2.2 GeV, and 2 pass -4.4 GeV). Measurements at 8-9.5 are doable.
  • Need to check whether the beam pipe will allow one to go to 8-9.5 degrees. (Dave Gaskell will look into this.)

SHMS HB mapping

  • Document and plots about mapping of B versus I at center of HB bore and the fringe fields in the beam region.
  • Measurements of B at bore center versus I when ramping magnet from 0 to +3900 and back to 0. Then switch polarity and ramp from 0 to -3900 and back to zero.
    • plot of absolute difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
    • plot of relative difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
    • Plot of difference in B between ramping up to +3900 and ramping up to -3900 versus current.
    • When ramping to negative currents there was a trip at I= -3139A. Plot of difference between first ramp to -3139A and the second.
  • Document and plots about mapping Of B versus z for five different x,y locations (center,top,bottomleft and right) for I = 2000, 3000, 3500 and 3900A.

HMS and SHMS Dipoles

SLITS and COLLIMATORS

SHMS Detector Positions

SHMS Characteristics

SHMS Drawings of magnets

Study of the SHMS resolution

  • Study of the SHMS resolution.

Old HMS information

SNAKE

Moved Snake section here.