Difference between revisions of "SHMS Optics Working Group"

From HallCWiki
Jump to navigationJump to search
Line 3: Line 3:
 
== Weekly Meetings ==
 
== Weekly Meetings ==
 
*Meetings will be held on Thursdays 11:30-12:30 in F228.  
 
*Meetings will be held on Thursdays 11:30-12:30 in F228.  
* Next meeting April 21st.
+
* Next meeting May 12th.
 
*Join by Bluejeans by phone and computer  +1.888.240.2560 (US Toll Free)  Enter Meeting ID: 653182486
 
*Join by Bluejeans by phone and computer  +1.888.240.2560 (US Toll Free)  Enter Meeting ID: 653182486
 +
 
== Notes from March 31st meeting ==
 
== Notes from March 31st meeting ==
 
*Tanja discussed initial work going through past run plans. She will present update at next meeting.
 
*Tanja discussed initial work going through past run plans. She will present update at next meeting.

Revision as of 11:48, 21 April 2016

Weekly Meetings

  • Meetings will be held on Thursdays 11:30-12:30 in F228.
  • Next meeting May 12th.
  • Join by Bluejeans by phone and computer +1.888.240.2560 (US Toll Free) Enter Meeting ID: 653182486

Notes from March 31st meeting

  • Tanja discussed initial work going through past run plans. She will present update at next meeting.
  • Discussion of beam pipe.


Notes from March 10th meeting

  • Need to check whether the beam pipe will allow one to go to 8-9.5 degrees. (Dave Gaskell will look into this.)
    • Using the 2nd plan configuration of the initial beam pipe ( SHMS to about 10, HMS to 10.5) it was checked by Dan Young that SHMS could go to 9 degrees drawing of beam pipe region.
  • Get the Q1 mapping information from Steve Lassiter.
  • Need to keep track of detector surveys. Contact Bert Metzger.
    • Not done.
  • Put code for setting field on wiki.
  • Double check to understand why there is a 0.7% difference between field at +3900A and -3900A.
    • The probe readings had not been corrected for non linearity in probe. Plot with correction shows less than 0.2% difference over all currents that drops to .02% at 3900A.
  • Change the effective length of HB by 4% to see effects on the optics. Look at sieve.
  • Need table for conversion of all magnet currents to momentum.
    • See HB and Q1 sections
  • Check with Steve Lassiter about what is exactly thinking of using to mitigate the HB stray fields. Wedges + C-section + iron pipe?
  • Work on run plans. (Rolf and Tanja)

Preparation plans

  • Magnets.
    • Determination of B versus I curve. Develop new code for setting SHMS. Revise HMS field setting codes.
    • Cycling procedure especially for HB. Look what is done for the HMS.
    • Double check that the magnet field between magnets are superpositions.
    • Survey of the positioning of magnets.
  • Carbon elastics at 2 pass.
  • Survey of collimators, detectors and beamline components.
  • Survey of HMS/SHMS pointing at different angles. Look into what was done in the past for HMS commissioning. Determine a list of angles for survey.
  • Need to come up with the sieve pattern as a function of quad settings.
  • Need to look at use of ideal dipole versus TOSCA field map for HB in COSY.
  • Checked with Howard about the quad field centering. The idea that Howard had didn't work. Need to rely on mapping data.
  • Integration of detector checkout and optics.

Carbon elastics

  • Results from Dipangkar for 1 pass- 2.2 GeV, and 2 pass -4.4 GeV). Measurements at 8-9.5 are doable.
  • Using the 2nd plan configuration of the initial beam pipe ( SHMS to about 10, HMS to 10.5) it was checked by Dan Young that SHMS could go to 9 degrees drawing of beam pipe region.
  • Beam energies available for Fall 2016 and all of 2017.
Pass Beam Energy (MeV)
1 2217
2 4317
3 6417
4 8517
5 10617
5.5 11667

SHMS HB

Sensitivity of scattering angle to HB central field setting

  • The distance, d1, from the targe center to the magnetic entrance of the HB is 138.4cm.
  • The effective length, d2, of the HB is nominally 75cm. This is presently used in COSY . Need to update using mapping data.
  • The distance, d3, from the magnetic exit of the HB to he sieve is 40cm.
  • The horizontal angle and position relative to the central ray are y and yp. Delta = 100*(p-pcentral)/pcentral .
  • At HB magentic entrance, yp_ent=yp_tar and y_ent(cm) =y_tar(cm) + d1*yp_tar(radians)
  • For the HB, the transport of yp and y only depends on delta and delta^2 terms.
    • yp_exit (mr) = -0.52*delta + 0.0052*delta^2 + yp_ent(mr)
    • y_exit (cm) = -0.019*delta + 0.00019*delta^2 + (d1+d2)*yp_tar(radians) + y_tar(cm)
    • y_sieve (cm) = y_exit + d3*yp_exit(radians)
    • To make it through y_sieve = 0 with y_tar = 0
      • y_exit = -d3*(-0.52*delta + 0.0052*delta^2 + yp_tar(mr))
      • (d1+d2+d3)*yp_tar(mr) = (0.019+0.52*d3)*delta - (0.00019+0.0052*d3)*delta^2
      • yp_tar (mr) = 0.153*delta - 0.00153*delta^2 .
    • So delta = 6.5% gives yp_tar = 1 mr.

Mapping

  • A Lakeshore Hall probe was used for the mapping measurements. The probe has a linearity error as a function of magnetic field which was measured by the company ( Table of data). This linearity error is different for positive and negative field directions. In the data table, the Error = abs(Measured Field)-abs(True Field). So for positive fields True Field = Measured Field - Error. For negative fields True Field = Measured filed + Error.
  • Document and plots about mapping of B versus I at center of HB bore and the fringe fields in the beam region.
  • Measurements of B at bore center versus I when ramping magnet from 0 to +3900 and back to 0. Then switch polarity and ramp from 0 to -3900 and back to zero.
    • plot of absolute difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
    • plot of relative difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
    • Plot of difference in B between ramping up to +3900 and ramping up to -3900 versus current.
    • When ramping to negative currents there was a trip at I= -3139A. Plot of difference between first ramp to -3139A and the second.
  • Document and plots about mapping Of B versus z for five different x,y locations (center,top,bottomleft and right) for I = 2000, 3000, 3500 and 3900A.
  • Presentation on the harmonic analysis of the HB using field measurements at radius of 5.9cm at center of magnet at currents of -1200,-2000,-3000,-3500,-3900 and +3900.
  • Table of momentum versus current:
Momentum (GeV) Current (A)
3.687 1200
6.110 2000
8.967 3000
10.283 3500
11.277 3900

Fringe fields

  • NIM article on the TOSCA calculations of SHMS fringe fields effects on the beam and mitigation.
  • For SHMS at 5.5 degrees, Drawing.
    • 2.065 inch diameter pipe fills HB cut-out.
    • Transition to 2.875 inch diameter pipe at 98 inches (250cm). Mechanical exit of HB is around 230cm. Pipe diamter set by the Q1 cut-out.
    • Transition to 5.5 inch diameter pipe at 165 inches (419cm). So smallest opening is 2.875/165/2 = +/-8.7mr .
  • For HMS at 10.5 degrees, Drawing of beam pipe region.
    • Notch in Q1 determines pipe diameter of 1.9 inches.
    • Transition to 2.875 diameter pipe is where the support is possible.
  • Presentation with more drawings of beam pipe configurations.
  • The integral Bdl along the beam line for different angles of SHMS set at 3900A with and without wedges.
SHMS angle HB Bdl (As built) HB Bdl ( with wedges)
5.5 0.117 Tm 0.070
10 0.035 0.0109
  • At 10 deg the fringe field from Q1 and Q2 is very small. theta_b = .299*.0109/11. = 0.0003 and displacement at the beam dump (50m upstream) is .0003*5000 = 1.5cm

SHMS Q1 mapping

  • Report on the analysis of the Q1 mapping data.
  • Plot of B versus I compared to OPERA.
  • Table of momentum versus current:
Momentum (GeV) Current (A)
6 1228
8 1672
10 2169
11 2454

HMS and SHMS Dipoles

SLITS and COLLIMATORS

SHMS Detector Positions

SHMS Characteristics

SHMS Drawings of magnets

Study of the SHMS resolution

  • Study of the SHMS resolution.

Old HMS information

SNAKE

Moved Snake section here.