NPS

From HallCWiki
Revision as of 17:12, 26 February 2023 by Ole (Talk | contribs) (Device list in EEL/108)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Neutral Particle Spectrometer (and related experiments)

Main NPS Wiki <-- Primary NPS wiki found here


Device list in EEL/108

  • When possible, I'm assigning addresses in the range 129.57.195.100--150.

PXE Booting

  • Devices on the 195 subnet are delivered PXE boot options via DHCP by the CNI DHCP server:
 next-server 129.57.195.43;                # cdaql3 (on 195 subnet in EEL/108)
 filename "linux-install/pxelinux.0"       # boot file
In-Progress

Misc Devices

  • hallc-nps-sw-2022 -- Main router
  • cdaql3 129.57.195.43 -- main DAQ computer (located in EEL/108)
  • nps-ps1 129.57.195.46 -- PortServer (See VTP Portserver Assignments below)
  • nps-pdu1 129.57.195.47 -- APC switchable power supply [user: hccuser]
    • nps-lv1 (outlet 1); nps-ps1 (outlet 8)]

Low Voltage Crates

  • nps-lv1 129.57.195.131 Weiner MPOD crate

High Voltage Crates

  • nps-hv1 129.57.195.130 CAEN 4527 Crate
  • nps-hv2 129.57.195.132 CAEN 4527 Crate

VME Crates (with module summary)

  • nps-crate1 129.57.195.121 VXS crate
    • nps-vme1 129.57.195.101
    • nps-vtp1 129.57.195.111
    • 15 F250 FADCs installed
  • nps-crate2 129.57.195.122 VXS crate
    • nps-vme2 129.57.195.102
    • nps-vtp2 129.57.195.112
    • 15 F250 FADCs installed
  • nps-crate3 129.57.195.123 VXS crate
    • nps-vme3 129.57.195.103
    • nps-vtp3 129.57.195.113
    • 15 F250 FADCs installed
  • nps-crate4 129.57.195.124 VXS crate
    • nps-vme4 129.57.195.104
    • nps-vtp4 129.57.195.114 (NOT INSTALLED YET)
    • 8 F250 FADCs installed (slots 3--10)
    • 1 CAEN 1190 TDC (in slot 20) for testing blocklevel > 1
    • (To be installed) 'Example' SIS3801 scaler for testing blocklevel > 1
    • (To be installed) LED driver modules

NOTE:

  • 0th 'full' crate is the SHMS calorimeter crate presently in use in the Hall (SHMS hut)
    • nps-vme0 129.57.168.xxx (Likely best to rename the VME SBC to follow general NPS naming scheme for clarity when the time comes.)
    • nps-vtp0 129.57.168.xxx (NOT INSTALLED YET)
    • It will be configured to use 15 (of its 16 FADCs) and will function identically to the first 3 'full' crates. (The 16th module will be a spare.)
    • It will not be coming to EEL/108 (of course).

VTP MAC / Portserver assignments

  • nps-vtp1 ce:ba:f0:03:00:ae 129.57.195.141
    • nps-crate1
    • Portserver: nps-ps1 2001
  • nps-vtp2 ce:ba:f0:03:00:af 129.57.195.142
    • nps-crate2
    • Portserver: nps-ps1 2002
  • nps-vtp3 ce:ba:f0:03:00:b0 129.57.195.143
    • nps-crate3
    • Portserver: nps-ps1 2003
  • nps-vtp4 ce:ba:f0:03:00:b1 129.57.195.144 (NOT INSTALLED YET)
    • nps-crate4
    • Portserver: nps-ps1 2004
  • nps-vtp5 ce:ba:f0:03:00:b2 129.57.195.145
  • nps-vtp6 ce:ba:f0:03:00:b3 129.57.195.146

Thermal / Humidity / Chiller Control and Readbacks

Using CrIO CompactRIO

  • dsg-nps-crio9045 129.57.195.26
  • nps-mux 129.57.195.36 (Spare Keysight)