Shms-reboot1.jlab.org
From HallCWiki
Jump to navigationJump to search<<< Main Page << Computing < Hall_C_Network
----
shms-reboot1.jlab.org
Schneider Electric Network Management Card AOS v6.4.6 (c) Copyright 2016 All Rights Reserved RPDU 2g APP v6.4.6 ------------------------------------------------------------------------------- Name : apcE5023E Date : 12/14/2007 Contact : Brad S Time : 20:14:19 Location : SHMS Electronics Hut User : apc Up Time : 0 Days 23 Hours 17 Minutes Stat : P+ N4+ N6+ A+
TCP/IP
The Network has started with the following settings : ----------------------------------------------------------------------- System IP : 129.57.168.155 Subnet Mask : 255.255.252.0 Default Gateway : 129.57.168.1 MAC Address : 00 C0 B7 66 8B 74
About System
Hardware Factory --------------- Model Number: AP7900B Serial Number: 5A1751E02813 Hardware Revision: B2 Manufacture Date: 12/20/2017 MAC Address: 00 C0 B7 E5 02 3E Management Uptime: 0 Days 23 Hours 20 Minutes
Network Management Card --------------- Model Number: 0G-1238 Serial Number: 5A1751E01167 Hardware Revision: 05 Manufacture Date: 12/18/2017
Application Module --------------- Name: rpdu2g Version: v6.4.6 Date: Nov 29 2016 Time: 13:28:51
APC OS(AOS) --------------- Name: aos Version: v6.4.6 Date: Oct 6 2016 Time: 17:46:25
APC Boot Monitor --------------- Name: bootmon Version: v1.0.8 Date: Apr 8 2014 Time: 10:59:40
Outlets
1- Outlet 1 ON 2- Outlet 2 ON 3- Outlet 3 ON 4- Outlet 4 ON 5- Outlet 5 ON 6- Outlet 6 ON 7- Outlet 7 ON 8- NDX Detector ON