==SHMS Magnets ==
 +
*Formulas used for setting current of SHMS magnets  during KPP
 +
{|border="1" align="center"
 +
! Magnet !!  Formula
 +
|-
 +
!HB !! Current = 330.05*p - 3.1784*p^2 + 0.4018*p^3
 +
|-
 +
!Q1 !! Current = 222.4*p - 7.709*p^2 + 0.6684*p^3
 +
|-
 +
!Q2 !! Current = 3661*p/11
 +
|-
 +
!Q3 !! Current = 2434*p/11
 +
|-
 +
!Dipole !!Current = 3450*p/11
 +
|}
 +
*[[SHMS Horizontal Bender]]
 +
  
 
== Scattering Chamber ==
 
== Scattering Chamber ==
 
* The scattering chamber window on the SHMS side is 0.020 inches thick  2024-T4 aluminum.
 
* The scattering chamber window on the SHMS side is 0.020 inches thick  2024-T4 aluminum.
== SHMS Magnets and Vacuum vessel ==
+
== SHMS Entrance Window and Vacuum vessel ==
 
* The Horizontal Bender entrance window is 0.010 inches  thick  2024-T3 aluminum.
 
* The Horizontal Bender entrance window is 0.010 inches  thick  2024-T3 aluminum.
 
* The dipole exit window is 0.020 inches thick 5056 aluminum.
 
* The dipole exit window is 0.020 inches thick 5056 aluminum.

Revision as of 12:56, 6 June 2017

Hallcheader.jpg


Fall 2017 Commissioning Plans

Spring 2017 KPP run

Hall C Links

Hall C

Hall C is one of four experimental halls at JLab.

Hall C Computing.

Hall C in the Press.

Basic Equipment in Hall C

Beamline

SHMS Magnets

  • Formulas used for setting current of SHMS magnets during KPP
Magnet Formula
HB Current = 330.05*p - 3.1784*p^2 + 0.4018*p^3
Q1 Current = 222.4*p - 7.709*p^2 + 0.6684*p^3
Q2 Current = 3661*p/11
Q3 Current = 2434*p/11
Dipole Current = 3450*p/11


Scattering Chamber

  • The scattering chamber window on the SHMS side is 0.020 inches thick 2024-T4 aluminum.

SHMS Entrance Window and Vacuum vessel

  • The Horizontal Bender entrance window is 0.010 inches thick 2024-T3 aluminum.
  • The dipole exit window is 0.020 inches thick 5056 aluminum.

Target

HMS Magnets and Vacuum Vessel

HMS Detectors

SHMS Detectors

DAQ

Controls

  • High Voltage
  • Spectrometer Controls (Use go_cmagnets command)
  • HMS and SHMS Collimator Control document.

Online Replay

Data Analysis

Monte Carlo

Hall C at 12 GeV