** [[Hall-C_HMS_DAQ_Failure_Modes | "HMS DC may be ringing (check replay now)" alarm]]
 
** [[Hall-C_HMS_DAQ_Failure_Modes | "HMS DC may be ringing (check replay now)" alarm]]
  
* [https://hallcweb.jlab.org/DocDB/0010/001002/002/Instructions-power-cycle-HallC-collimators.pdf Instructions for power cycling the drive controllers for the HMS/SHMS collimators].  
+
* Collimator, Sieve Controls
 +
** EPICS screens can be found at jmenu -> <search for> "HMS coll" and you'll see both entries
 +
*** The usual collimator settings are HMS : "Large Collimator" and SHMS : "Collimator".
 +
*** The usual sieve settings are "HMS: Sieve" and SHMS: "Centered Sieve"
 +
** [https://hallcweb.jlab.org/DocDB/0010/001002/002/Instructions-power-cycle-HallC-collimators.pdf Instructions for power cycling the drive controllers for the HMS/SHMS collimators].  
 
** [https://hallcweb.jlab.org/DocDB/0008/000828/001/hallc_collimators.pdf More detailed info on collimator controls]. Also includes description of the collimators.
 
** [https://hallcweb.jlab.org/DocDB/0008/000828/001/hallc_collimators.pdf More detailed info on collimator controls]. Also includes description of the collimators.
**  EPICS screens can be found at jmenu -> <search for> "HMS coll" and you'll see both entries
+
 
** The usual collimator settings are HMS : "Large Collimator" and SHMS : "Collimator".
+
 
* [[Scalers|Hall C Scalers & xscalers instructions]] for HMS and SHMS.
 
* [[Scalers|Hall C Scalers & xscalers instructions]] for HMS and SHMS.
  

Revision as of 04:11, 23 March 2020

NOTE: If you can't solve the problem in 1 hour you MUST then contact the Run Coordinator! (See also Experts on call)

Polarized He3 Target Information

Pol He-3 Target Screen Setup / How-tos

Polarized He3 Target Information

Pol He3 Operational Restrictions (raster, beam current limits, etc)

General How-to's

  • Make HCLog entries using the logbook page, or by running 'hclog' in a terminal.
    • Please be concise, but clear. Assume you will need to search for, and understand, an entry 12 months from now (or longer).
  • Hall C Raster
    • If problems call Raster experts in order of listed on Expert on call page.
    • Raster procedure is located at Hall C Fast Raster Setup Procedure
    • The raster X and Y signals that go into the DAQ are also shown on an oscilliscope in rack CH03B14. See logbook entry for a movie of good oscilliscope signals. The X and Y should be 90 degrees out of phase and the amplitude variation in sync.
    • If raster signal's amplitude variation is not in sync, then ask MMC to go to the "Waveform Generator" page ( top right corner of the Hall C fast raster page). On the "Waveform Generator" page have MCC click on the "SYNC ARB" button.
    • If raster signal's phase is not 90 degrees, then ask MMC to go to the "Waveform Generator" page ( top right corner of the Hall C fast raster page). On the "Waveform Generator" page have MCC click on the "SYNC PHASE" button.

Spectrometer Magnets

How to Rotate the HMS and SHMS

SHMS Detectors

HMS Detectors

Polarized 3He target in Hall C

Hall C Cryo-target