NOTE: If you can't solve the problem in 1 hour you ''MUST'' then contact the Run Coordinator!'''  (See also [[Experts on call]])
 
NOTE: If you can't solve the problem in 1 hour you ''MUST'' then contact the Run Coordinator!'''  (See also [[Experts on call]])
 
== Polarized He3 Specific Information ==
 
* [[Media:Glass_Cell_Target_Change_Procedure.pdf | Procedure for Moving Between Target Cells (pdf)]] [[Media:Glass_Cell_Target_Change_Procedure.odp | (ODP)]]
 
* [[Media:SIMPLIFIED REFERENCE CELL PROCEDURES.pdf|Reference Cell Fill Procedure (PDF)]] ([[Media:SIMPLIFIED REFERENCE CELL PROCEDURES.docx|docx]])
 
* [[Pol He-3 Target Screen Setup|Pol He-3 Target Screen Setup / How-tos]]
 
* [[Pol_He-3_Target_Information|Polarized He3 Target Information]]
 
* [[Pol_He-3_Operational_Restrictions|Pol He3 Operational Restrictions (raster, beam current limits, etc)]]
 
* [[Polarized_Helium-3_Experiments#New_Online_Monitoring_Instructions|Online Analysis Instructions]]
 
* [[How to check for Scraping on Target Cell Walls|How to check for Scraping on Glass Target Cell Walls]]
 
* [[Ramp Rate Lock | How to check if the beam current ramp protection is on (Pol He3)]]
 
* [[Charge Feedback Parity DAQ]]
 
  
 
== General How-to's ==
 
== General How-to's ==
Line 60: Line 49:
 
*[[Hall C Drift Chamber Threshold Controls]]
 
*[[Hall C Drift Chamber Threshold Controls]]
 
* Hall C BPMs: Run '''go_bpms''' from the ''cdaq'' account
 
* Hall C BPMs: Run '''go_bpms''' from the ''cdaq'' account
*[[Target BPMs | How to open target BPM screen]] (This display projects the BPM positions to the target (PolHe3))
 
 
*[[Hall C Harps | How to see results of Hall C harp scans]]
 
*[[Hall C Harps | How to see results of Hall C harp scans]]
 
*[[Hall C YAG Viewer | How to bring up the Hall C YAG Viewer camera]]
 
*[[Hall C YAG Viewer | How to bring up the Hall C YAG Viewer camera]]

Revision as of 17:13, 12 August 2021

NOTE: If you can't solve the problem in 1 hour you MUST then contact the Run Coordinator! (See also Experts on call)

General How-to's

  • Make HCLog entries using the logbook page, or by running 'hclog' in a terminal.
    • Please be concise, but clear. Assume you will need to search for, and understand, an entry 12 months from now (or longer).
  • Hall C Raster
    • If problems call Raster experts in order of listed on Expert on call page.
    • Raster procedure is located at Hall C Fast Raster Setup Procedure
    • The raster X and Y signals that go into the DAQ are also shown on an oscilliscope in rack CH03B14.
    • Instructions for circular raster ( not using as of AUg 2021)
      • See logbook entry for a movie of good oscilliscope signals. The X and Y should be 90 degrees out of phase and the amplitude variation in sync.
      • If raster signal's amplitude variation is not in sync, then ask MMC to go to the "Waveform Generator" page ( top right corner of the Hall C fast raster page). On the "Waveform Generator" page have MCC click on the "SYNC ARB" button.
      • If raster signal's phase is not 90 degrees, then ask MMC to go to the "Waveform Generator" page ( top right corner of the Hall C fast raster page). On the "Waveform Generator" page have MCC click on the "SYNC PHASE" button.

Spectrometer Magnets

How to Rotate the HMS and SHMS

SHMS Detectors

HMS Detectors

Polarized 3He target in Hall C

Hall C Cryo-target

Legacy Documentation