Difference between revisions of "Main Page"

From HallCWiki
Jump to navigationJump to search
Line 77: Line 77:
  
 
== Target ==
 
== Target ==
*Spring 2017 KKP run
+
===Spring 2017 KKP run===
**[https://hallcweb.jlab.org/DocDB/0008/000856/001/HallCTargetConfiguration2-6-17.docx Word doc] describing the targets and their thicknesses. Also available at [https://logbooks.jlab.org/entry/3456394 logbook entry].
+
*[https://hallcweb.jlab.org/DocDB/0008/000856/001/HallCTargetConfiguration2-6-17.docx Word doc] describing the targets and their thicknesses. Also available at [https://logbooks.jlab.org/entry/3456394 logbook entry].
**[https://hallcweb.jlab.org/DocDB/0008/000856/001/TGT-301-1001-0110.pdf Drawing] of target ladder. Also available at [https://misportal.jlab.org/jlabDocs/document.seam?id=94157 JLab document repository].
+
*[https://hallcweb.jlab.org/DocDB/0008/000856/001/TGT-301-1001-0110.pdf Drawing] of target ladder. Also available at [https://misportal.jlab.org/jlabDocs/document.seam?id=94157 JLab document repository].
 +
===Fall 2017 run ===
 +
*[https://logbooks.jlab.org/entry/3481732 Logbook entry] on the Fall target configuration which has links to file describing the targets and their thicknesses and a file with the mechanical drawing of the target ladder.
  
 
== HMS Magnets and Vacuum Vessel ==
 
== HMS Magnets and Vacuum Vessel ==

Revision as of 15:30, 17 August 2017

Hallcheader.jpg


Fall 2017 Commissioning Plans

Spring 2017 KPP run

Hall C Links

Hall C

Hall C is one of four experimental halls at JLab.

Hall C Computing.

Hall C in the Press.

Basic Equipment in Hall C

Beamline

SHMS Magnets

  • Formulas used for setting current of SHMS magnets during KPP
Magnet Formula
HB Current = 330.05*p - 3.1784*p^2 + 0.4018*p^3
Q1 Current = 222.4*p - 7.709*p^2 + 0.6684*p^3
Q2 Current = 3661*p/11
Q3 Current = 2434*p/11
Dipole Current = 3450*p/11

Scattering Chamber

  • The scattering chamber window on the SHMS side is 0.020 inches thick 2024-T4 aluminum.

SHMS Entrance Window and Vacuum vessel

  • The Horizontal Bender entrance window is 0.010 inches thick 2024-T3 aluminum.
  • The dipole exit window is 0.020 inches thick 5056 aluminum.

Target

Spring 2017 KKP run

Fall 2017 run

  • Logbook entry on the Fall target configuration which has links to file describing the targets and their thicknesses and a file with the mechanical drawing of the target ladder.

HMS Magnets and Vacuum Vessel

HMS Detectors

SHMS Detectors

DAQ

Controls

  • High Voltage
  • Spectrometer Controls (Use go_cmagnets command)
  • HMS and SHMS Collimator Control document.

Online Replay

Data Analysis

Monte Carlo

Hall C at 12 GeV